Skip to content
Align your AI

The problem space · Internals · Stale monitors

Align your AI Internals against stale monitors

A probe that reads a model's internal activity can fail on inputs, attacks or model changes it was not fitted to.

Internals
the activity inside the model
Stale monitors
a check built for the old model
Internals 14/15Stale monitors 1/15The whole map

Ways it goes wrong

No public incident is known yet; the evidence comes from research. Reading a model's internals means watching the numbers that rise and fall inside it as it works. A probe is a small check fitted to that activity. Probes for Gemini failed when inputs grew from short to long1. Crafted inputs often cut a probe's catch rate from 100% to 0%, and the attack still worked 90% of the time2. In one study, fine-tuning often left probes stale3.

  • 2026

    Gemini's probes and long inputs

    Researchers at Google found that probes reading Gemini's internal activity failed to carry over from short inputs to long ones, and needed new designs and more varied training data.

    Source: arxiv.org/abs/2601.11516

  • 2024

    Activity reshaped to slip past probes

    Researchers crafted inputs that changed a model's internal activity so that probes trained to spot harmful requests missed them, while the attacks still worked.

    Source: arxiv.org/abs/2412.09565

What people do about it

Google's researchers found that pairing probes with a second model asked to judge the request gave the best accuracy at low cost1. Their findings informed probes deployed in Gemini for users1. The staleness study recommends re-checking probes after every fine-tune3.

  • Test probes on long and multi-turn inputs

    Checks each probe on long conversations as well as short prompts before trusting its verdicts.

  • Pair a probe with a different check

    Runs a second model that judges the request, so one blind spot does not decide alone.

  • Re-fit probes after any weight change

    Scores each probe again on labelled examples from the new model, and re-fits it when it slips.

    Resource: NNsight

Where we touch it

Study and insights coming soon: Do safety monitors survive fine-tuning?

Sources

  1. Kramár et al., “Building Production-Ready Probes For Gemini”, arXiv 2601.11516. https://arxiv.org/abs/2601.11516. Accessed 2026-10-23. ↩ ↩2 ↩3

  2. Bailey et al., “Obfuscated Activations Bypass LLM Latent-Space Defenses”, arXiv 2412.09565. https://arxiv.org/abs/2412.09565. Accessed 2026-10-23. ↩

  3. Duan, “Do Activation Monitors Survive Model Updates? Benchmarking, Predicting, and Repairing Activation-Monitor Staleness”, arXiv 2606.15980. https://arxiv.org/abs/2606.15980. Accessed 2026-10-23. ↩ ↩2